Strany 1 - Operators Manual

SE95052Operators ManualInstallation, Operation & ServiceGas 25 Gallon KettleMODELS:KGL-25KGL-25-TKGT-25-TKGT-251333 East 179th St., Cleveland, Ohi

Strany 2 - FOR THE USER

CARE AND CLEANINGYour kettle must be cleaned regularly to maintain itsfast, efficient cooking performance, and to ensure itscontinued safe, reliable o

Strany 3 - TABLE OF CONTENTS

8FAUCET ASSEMBLY(optional)ITEM PART DESCRIPTION QTY.NO. NO.1.33//44"" SSPPOOUUTTKE50825-7 FOR STATIONARY KETTLES . . . . . . . . . . .1KE5

Strany 4 - INSTALLATION

9ITEM NO. PART NO. DESCRIPTION QTY.1. KE01927-1 COMPONENT MOUNTING PLATE (STATIONARY MODELS) . . . . . . . . . . . . . . .1KE01927 COMPONENT MOUNTING

Strany 5 - CLEANING

10ITEM NO. PART NO. DESCRIPTION QTY.1. KE54897-1 MANIFOLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 6 - - TILTING MODELS

1112345672" TANGENT DRAW-OFF VALVEITEM NO. PART NO. DESCRIPTION QTY.1. - 7. KE50972-B DRAW-OFF ASSEMBLY . . . . . . . . . . . . . . . . . . . . .

Strany 7 - - STATIONARY MODELS

12ITEM NO. PART NO. DESCRIPTION QTY.1. KE00099 ADJUSTABLE FOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 8 - OPERATING INSTRUCTIONS

1313. FI05198-5 COMPRESSION ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114. FI00565-6 NIPPLE 3/8 NPT

Strany 9 - APPROXIMATE BOILING TIMES

1423. FA19177 HEX SOCKET SET SCREW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124. FA20047 JAM NUT . . . . . .

Strany 10 - CLEANING INSTRUCTIONS

15VIEW "A"COMPONENT MOUNTING BOXWITH LID REMOVEDVIEW "B"MANIFOLD & BURNERTUBE PIPING DETAIL122531217 8 106L226272528 29 28 30L

Strany 11 - SERVICE PARTS

16ITEM NO. PART NO. DESCRIPTION QTY.1. KE00099 ADJUSTABLE FOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 12 - COMPONENT MOUNTING PLATES

FOR THE USERIMPORTANTPOST IN A PROMINENT LOCATION, INSTRUCTIONS TO BE FOLLOWED IN THE EVENTTHE USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY

Strany 13 - BURNER ASSEMBLY

17CONSOLECONTROLSITEM NO. PART NO. DESCRIPTION QTY.1. SE00114 POTENTIOMETER WITH ON/OFF SWITCH, C/W ITEM #2 . . . . . . . . . . . . . . . . .12. KE510

Strany 14

18HINGE ASSEMBLY153213126471181099ITEM NO. PART NO. DESCRIPTION QTY.1. - 11 SE00120-1 Hinge Assembly . . . . . . . . . . . . . . . . . . . . . . . .

Strany 15 - - TILTING MODELS (pg. 1 of 3)

19MAINTENANCEALL SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN.Cleveland Range equipment requires little preventative maintenance. We do

Strany 16 - - TILTING MODELS (pg. 2 of 3)

20SAFETY INSPECTION CHECKLIST- TILTING MODELS (pg. 1 of 2)Regular inspection and maintenance of units is essential to obtain trouble free and safe ope

Strany 17 - - TILTING MODELS (pg. 3 of 3)

21SAFETY THERMOSTAT:✘ Proberemovedpartially✘ Proberemovedcompletely✘ Thermostatelectricallybypassed✔Probefullyinsertedin tubeWiring is properlycon

Strany 18

22LUBRICATION PROCEDURELubricate the following parts every three months toinsure smooth operation and reduce wear.TRUNNIONHOUSING,WORM SCREWAND TILT G

Strany 19 - - TILTING MODELS (pg. 2 of 2)

23CALIBRATING PROCEDURE1. Insure the unit has a vacuum before you begincalibrating procedures. If unit requires venting referto Kettle VENTING INSTRUC

Strany 20 - CONTROLS

RESERVOIR FILLPROCEDURESThe kettle's water level must be maintained at theproper level. Under normal operating conditions, thesealed water reserv

Strany 21 - HINGE ASSEMBLY

25Draining Procedure1. Shut off gas supply.2. Disconnect gas line and electrical connection.3. Remove bolts holding kettle to table.4. Pull ring on pr

Strany 22 - MAINTENANCE

KETTLE VENTINGINSTRUCTIONS1. Remove guard bracket frompressure relief valve/gaugeassembly.2.Set On-Off Switch/TemperatureControl to to "10 "

Strany 23 - TILTING MODELS (pg. 1 of 2)

TABLE OF CONTENTSInstallation Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Shipping Damage Ins

Strany 24 - TILTING MODELS (pg. 2 of 2)

27WIRING DIAGRAMTABLE-TOP GAS KETTLE, 120-240 VOLTS KE90424-F

Strany 25 - INSTRUCTIONS

28SEQUENCE OF OPERATIONS1. To turn the unit on, turn the switch to the onposition. Power is sent to primary side of the120vac/16vac transformer. Pow

Strany 26 - PROCEDURE

29PROBLEM:KGL-25Kettle Won'tHeatDoes red lightcome on when unitis first turned on?Does red light gooff shortly afterunit is turned on?YesAdd wate

Strany 27 - DISTILLED WATER REQUIREMENTS

30PROBLEM:KGL-25Kettle NotHot EnoughWith kettle potempty andtemperature knobset at 10, is thetemperature of thesurface of the pot260 degrees?Unit isop

Strany 28 - DANGER: EXTREMELY

31PROBLEM:KGL-25Kettle GetsToo HotWith the kettleempty and thetemperature set at10, is the surfacetemp 260-265degrees?The kettle is workingproperly.Ye

Strany 29 - LEAK TEST PROCEDURE:

32ONMARCHEENCENDIDOACCESOANPAUSE, INTERRUPTIONPAUSE, INTERRUPTIONPAUSA, INTERRUPCIONPAUSA, INTERRUZIONEPAUSE, UNTERBRECHUNG RESETRÉENCLENCHERRECONECT

Strany 30 - WIRING DIAGRAM

33LOW WATERNIVEAU BAS DE L'EAUNIVEL DE AGUA BAJOLIVELLO BASSOWASSERSTAND NIEDRIGIGNITION FAILUREPANNE D'ALLUMAGEFALLO DE ENCENDIDOMANCATA AC

Strany 31 - SEQUENCE OF OPERATIONS

1INSPECTIONBefore unpacking visually inspect the unit for evidenceof damage during shipping.If damage is noticed, do not unpack the unit, followshippi

Strany 32 - Kettle Won't

2ELECTRICALENSURE THE ELECTRICAL SUPPLY MATCHES THEKETTLE'S REQUIREMENTS AS STATED ON THERATING LABEL.A cord and plug are supplied with the unit.

Strany 33 - Hot Enough

3SPECIFICATIONSOVERALL DEPTHNOTESFOOT LOCATION &FLOOR DRAIN DETAILFLANGEDFOOT DETAILSPECIFICATION DRAWING- TILTING MODELS

Strany 34 - Kettle Gets

4SPECIFICATIONS NOTESFOOT LOCATION &FLOOR DRAIN DETAILFLANGEDFOOT DETAIL9/16"14 mm120ºTYP1" (25 mm)MAX. ADJUSTMENT1 5/8" (42 mm) Ø

Strany 35 - (page 1 of 2)

568543217OPERATING INSTRUCTIONSITEM # DESCRIPTION FUNCTION1. Tilt Wheel (tilting models only) Used for tilting the kettle.2. Vacuum/Pressure Gauge In

Strany 36 - (page 2 of 2)

6OPERATING THE KETTLEDO NOT ATTEMPT TO OPERATE THIS APPLIANCEDURING A POWER FAILURE.KEEP APPLIANCE AND AREA FREE AND CLEAR OFCOMBUSTIBLES.DO NOT LEAN